link to photo album

Cikki Animal & Poultry

For International clients 1 KCal = 3.968 BTU

Far The Best Quality
Direct-Fired Gas Circultating Air heater


According to Out Customers Results.

Inside Installation

Low pressure working (20 - 40 mbar) by LPG and Natural gas, allows the inside installation The re-circulation unit allows the air to be taken from either inside or outside

Outside Installation

Weahterproof case with IP44 protection degree approved cabinet The re-circulation unit allows the aie to be taken from either inside or outside

Accessories

Air Re-Circulating unit

The air supply re-circulating unit can be installed allowing to use outside air, all inside air, or a mixture. This guarantees the best of all worlds and saves energy by up to 30%.

Air Duct

The output air duct is provided with a gravity damper, to be used with outdoor installation of the heater. This feature prevents heating leaks in th epassage of the inside air to the outside when the heater is not working.

Wall Brackets

Wall brackets for both underneath or overhead mounting. Inclusive of hoixting eyebolts, to hang the heater at the ceiling with chains or metal cables.

A Superior Quality Which Fears No Comparison, With a New 70 KW Capacity.

Fully Approved


Quality and Safety
Cikki is certified CE0694BL2996
CIKKI certified CE0694BL2996, has been designed and produced in accordance with the European Gas Directive CEE 90/396 and following the ISO 9000 rules. It is IP44 certified and it is independently tested prior to despatche.

Highest Reliability

The peculiarity of CIKKI air heater is the burner with its special gas deflector and its double electronic ignition with a high power spark and with flame control by ionisation. The unique patented system eliminates any risk of malfunction, granting a perfect lighting and a better combustion, assuring constant high quality as years go. It is also a much stronger ignition system, compared with other types.

Performances

Up to 70 kW heating capacity output, 100% thermal efficiency with only 0,4% CO2 in the air-flow, both methane, propane and butane working gas burner which is anti-dust adhesion, up to 30 meters air-flow lauch blower, -10/+40 degrees working field: you won't ask for more.

Easy Maintenance


Cikki Assembled with accessoires
Quick-disassembly of the cabinet without disconnecting wires. It assures very easy accessibility and simply field serviceably the grower. Unit is accessible also through side swinging doors.

Sturdy Item

An extremely strong pre-painted galvanised steel cabinet, a thick high temp aluminized steel combustion chamber, a heavy duty thermally protected alluminium electric motor with cooling fins, a solid powerfull blower, a cast iron burner: Cikki is indestructible.

Dual Application, Inside-Outside Mounting

Cikki is IP44 protection degree approved i.e. absolutely weather proof. It has special anti-condensate deflect protect better all components. It can be installed either inside or outside the poultry and livestock confinement buildings using same heater for either application.

Model Cikki 70
CE CERTIFICATION CE0694BL2996
Heating capacity kW 70
Kcal/h 60.200
Consumption:  
Natural gas G20 m3/h 7,02
Propane gas G31 kg/h 5,44
Butane gas G30 kg/h 5,52
Air throw m 30
Air output at + 20°C m3/h 2.000
Temperature deviation °K 130
Classification TYPE A2
Electrical supply   230V ~ 50 Hz
Fan's electric power W 300
Electrical protection degree IP 44
Gas connection Inch 1/2
Net Weight Kg 60

Point of Interest

  • CE approved
  • Completely tested
  • IP44 protection degree
  • Supplied by low gas pressure - less than 40 mbar - which allows an inside installation of the heater
  • Inside and outside application
  • Quick-disassembly cabinet without disconnecting wires
  • 100% efficency with only 0,4% CO2
  • Up to 70kW heating capacity output
  • Cast iron gas burner using methane, propane or butan
  • Double electronic ignition and flame control by ionisation
  • Top safety with double thermostats and flowswitch
  • The flame is completely inside the heater and is protected by the combustion chamber, therefore it is invisible compared to many other systems
  • High pressure radial fan, which assures a very high air throw speed from the air duct, causing an induction environment's air drag with the following consequences:
    1. large warm air diffusion
    2. fast air mixing
    3. no air stratification
    4. it s possible to install the heaters on one side of the shed
  • Air supply through a grided anti-mouse panel positioned on the bottom, that permits to install the air re-circulating unit to take either inside or outside air
  • Without exhaust flue