Oil Heat System
For International clients 1 KCal = 3.968 BTU
Heatmaster series 125, 203, 304, 404
"Livingroom" comfort anywhereThis fully automatic furnace
is sized right to meet your needs for efficient dependable general purpose
heating. It gives you many construction and quality features including :
Electric welded steel construction throughout for years of trouble-free service,
a double welded fire box, 12" adjustable elbows to connect to standard
ductwork, and vents which can be custom built to your specifications.
Standard features :
- 12" heat distribution elbows
- All controls and wiring
- 55othermostat
- Single stage oil pump ( 10 ft.lift )
- Shielded Cad - Cell Flame sensor
- Breaker disconnect box
- Adjustable air shutter for better combustion efficiency
- Flame retention burner
- Blower motor
- Model 125 - 3/4 HP; 203 - 3/4 HP; (110V-6AMP)
- Model 304 - 3/4 HP - 7 1/2 AMP; 404 - 1 HP - 9 AMP; (110V)
- Fully shielded blower assembly
- Barometric damper
- Summer fan switch
- 10 year warranty
Options :
- 2 - stage fuel pump ( 21 ft. lift )
- Low temperature thermostat ( 30o)
| MODEL |
BTU |
GALLONS
PER HOUR |
OVERALL
WIDTH |
OVERALL
LENGTH |
OVERALL
HEIGHT |
VENT
PIPE |
SHIPPING
WEIGHT |
| HM404 |
400,000 |
2.75 |
36" |
87" |
59" |
8" |
1,000 lbs. |
| HM304 |
300,000 |
2.00 |
31" |
85" |
53" |
8" |
750 lbs. |
| HM203 |
200,000 |
1.25 |
26" |
77" |
53" |
8" |
640 lbs. |
| HM125 |
125,000 |
.85 |
23" |
70" |
50" |
6" |
500 lbs. |
Oil Heat System : Counterflowseries
150, 200, 300, 400
Counterflow Standard Features:Same as Heatmaster Features Except...
- Fan and limit control switch
- Breaker disconnect box
- Blower motor:
- 200 : 3/4 HP - 7Amp
- 300 : 3/4 HP - 7 1/2 Amp
- 400 : 1 HP - 9.2 Amp
- 10 year warranty
Options:
- 2 - stage fuel pump ( 21 ft.lift )
- Low temperature thermostat ( 30o)
- Over size blower ( Mag.air )
| MODEL |
BTU |
GALLONS
PER HOUR |
OVERALL
WIDTH |
OVERALL
LENGTH |
OVERALL
HEIGHT |
VENT
PIPE |
SHIPPING
WEIGHT |
| 400 |
400,000 |
2.75 |
38" |
85" |
52" |
8" |
900 |
| 300 |
300,000 |
2.00 |
31" |
77" |
50" |
8" |
790 |
| 200 |
200,000 |
1.25 |
28" |
74" |
48" |
8" |
650 |
Oil Heat System :Royal oil series
240, 320, 400
Standard
Features :
- All controls and wiring
- 55othermostat
- Single stage oil pump ( 10 ft. lift )
- Shielded Cad - Cell flame sensor
- Breaker disconnect box
- Horizontally - directed are flow pattern
- Jets easily cleaned - no plugging
- Stainless steel baffling
- Fully shielded blower assembly
- Barometric damper
- Summer fan switch
- 10 year warranty
High Performance
- Easily serviced by home service personnel
- Adjustable air shutter for better combustion efficiency.
- Exhaust fans in greenhouses or warehouses should not run while furnaces
are operating.
- The chimney from the furnace to the draft cap should not be reduced in
size.
Options :
- 2 - stage fuel pump ( 21 ft. lift )
- Low temperature thermostat ( 30o)
| MODEL |
BTU |
GALLONS
PER HOUR |
OVERALL
WIDTH |
OVERALL
LENGTH |
OVERALL
HEIGHT |
VENT
PIPE |
SHIPPING
WEIGHT |
| 240 |
240,000 |
1.65 |
31" |
48" |
51" |
8" |
500 lbs |
| 320 |
320,000 |
2.25 |
35" |
54" |
51" |
8" |
680 lbs |
| 400 |
400,000 |
2.75 |
45" |
70" |
58" |
8" |
1000 lbs |
Oil Heat System :Quantum series
210
Standard Features:
- Light weight " Hang Anywhere "
- All controls wired for installation
- 55othermostat
- Single stage oil pump ( 10 ft. lift )
- Cad Cell Flame Sensor
- Fan and limit control switch
- Breaker disconnect box
- 1/3 HP capacitor start fan motor
- 4 - blade " Quite Quiet " high efficiency fan (24")
- Fully " Finger Protected " fan guard
- Barometric damper included
- 10" clearance from walls suggested
- High fuel efficiency
Design Features :
- Useable in horizontal air flow patterns for large building heating.
- Easily serviced Beckett Burner ( #2 heating oil )
- Adjustable air shutter for better combustion efficiency
- Flame retention burner ( high efficiency )
Options :
- 2 - stage fuel pump (21 ft.lift )
- Low temperature thermostat ( 30o)
Warranty ;
- 5 years on heat exchanger ( pro - rated )
- 6 months on components ( replacement of parts only )
| MODEL |
BTU |
GALLONS
PER HOUR |
OVERALL
WIDTH |
OVERALL
LENGTH |
OVERALL
HEIGHT |
VENT
PIPE |
SHIPPING
WEIGHT |
| Q-210 |
210,000 |
1.50 |
42" |
44" |
52" |
8" |
550 lbs |
Propane / Natural Gas Quantum 180
Standard Features:
- Light weight " hang Anywhere " / " Set Anywhere"
- All controls wired for installation
- 55othermostat
- Available in LP or natural gas models
- Adjustable outlet louvers
- Fan and limit control switch
- Breaker disconnect box
- 1/3 H.P. capacitor start fan motor
- 4 - blade "Quite Quiet " High efficiency fan (24")
- Fully " Finger Protected " fan guard
- Floor or ceiling mounted
- Draft hood included
- Simple atmospheric burner
- No sensitive ignition controls to get wet
- High efficiency 78%+
- Cast iron " Long Life " burner
- Brass pre - sized burner jets
- 5 Year warranty
Options :
- Low temperature thermostat ( 30o)
- Electric ignition
| MODEL |
BTU/HR |
OVERALL
WIDTH |
OVERALL
DEPTH |
OVERALL
HEIGHT |
VENT
PIPE |
SHIPPING
WEIGHT |
| Q-180 |
180,000 |
36" |
41" |
48" |
6" |
350 lbs |
Propane / Natural Gas Royal Heat 240,
360
Featuring :
- Jet / Vortex combustion design
- Easy - out burner service tray
- Draft Diverter included
- Horizontally - directed air flow pattern
- Jets easily cleaned - no plugging
- Stainless steel baffling
- Breaker disconnect box
- 10 Year warranty
| MODEL |
BTU/HR |
OVERALL
WIDTH |
OVERALL
DEPTH |
OVERALL
HEIGHT |
VENT
PIPE |
SHIPPING
WEIGHT |
| 240 |
240,000 |
31" |
48" |
51" |
8" |
550 lbs |
| 360 |
360,000 |
36" |
54" |
51" |
8" |
680 lbs |
Click Here See Heat Photo Album
section
Index
Page | Heating Systems | Heating
Systems & Technology
Hieating Systems
for All Types | Natural
Gas/Propane
Oil Heat | Boilers | Mobile
Gas/Propane | Mobile
Oil | Waste Oil
Cikki Animal/Poultry | In/under Bench
|